The electrical equipment aboard ship is inspected and tested during the complete engine survey which occurs every four years.
Such a survey is prescribed under the Rules and Regulations for the Classification of the Ship (depending where your ship is registered)
The electrical survey guidance in this report is based on the periodical survey regulations of Lloyd’s Register of Shipping, London.
Other classification societies have their own rules which although similar to Lloyd’s,shouldbe consulted prior to an electrical survey.
Classification Societies
American Bureau of Shipping, New York
Bureau Veritas, Paris
GermanischerLloyd, Germany
Nippon KaijiKyokai, Tokyo
DetNorske Veritas, Oslo
RegistroItalianoNavale, Genoa
USSR Register of Shipping, Moscow
Electrical equipment and services aboard ship must also meet the minimum standards by various national and international organization.
For UMS operation, a survey of the associated alarms, controls and fire detection is required.
For tankers/gas carriers and other ships transporting flammable cargo, an additional survey of all electrical equipment in hazardous areas is carried out during each docking survey and annual survey.
*The surveyorwill require that main and emergency generators are clean, respond correctly to controls and load changes, and show stable operation when required to run in parallel with other generators.
Generator windings on stator and rotor must be free of:
Dust
Oil
Moisture
A visual check will be made for any obvious deterioration, abrasion, or cracking of the insulation around the end winding coils of the stator.
An insulation testto earth and between stator phase windings (if neutral point can be disconnected at the terminal box) should be carried out while the machine is still hot after running on load.
Question:
Would IR reading of 0.5 MΩ to earth be acceptable?
Answer:
Although a minimum of 1MΩ is generally specified for new equipment, Lloyd’s rules suggest that 0.1 MΩis acceptable. However, most surveyors would insist on at least 2kΩ/volt, i.e. 440kΩ, say, 0.5MΩ as a reasonable minimum value for a 440V generator.
Comments
JeromePurificacion
Wed, 03/12/2014 - 02:33
Permalink
some terms
Brensien Asdain
Wed, 03/12/2014 - 02:42
Permalink
Niigata electro assignment
Jamar Salahuddin
Wed, 03/12/2014 - 02:54
Permalink
it helps a lot
Brensien Asdain
Wed, 03/12/2014 - 03:02
Permalink
Niigata electro assignment
aq po c aran
Wed, 03/12/2014 - 07:10
Permalink
SAKAI- 3CL ARANJUEZ
Roed_P
Wed, 03/12/2014 - 08:08
Permalink
The article is marvelous. It
Aaron John Barcelo
Mon, 03/31/2014 - 07:40
Permalink
NOSHIRO MARCH 31
ejmediavillo
Mon, 03/31/2014 - 07:56
Permalink
Mediavillo, EPNM - Noshiro
Celino Mangundayao
Tue, 04/01/2014 - 01:47
Permalink
It really helps
Add new comment